Shanghai 3S Global Company Limited

Intelligent Pump Starter for Well & Building Water Systems, 90-250V

Small Building Pump Control,Automatic Protection System,Single Phase Water Pump Controller
Intelligent Pump Starter for Well & Building Water Systems, 90-250V
Intelligent Pump Starter for Well & Building Water Systems, 90-250V

Intelligent Pump Starter for Well & Building Water Systems, 90-250V

Product Category : Dedicated Pump Controller - Booster Pump Controller

Model: 3S-S11-040

Chip: ST

Relay: HongFa

MCB/AC Contactor: CHINT

Working Pump: 0.37-4kW

Startup Method: DOL (Direct On Line)

Rated Voltage&Frequency: Single-phase AC110-250V, 50/60Hz

Enclosure Type: IP55

Protections: 13 types protection

Signal Compatibility: Digital, 4–20mA analog, and 0–5V analog

Working Environment: -20℃~+55℃, 20 to 95% RH

    Leave a message

  • Close

Intelligent Protection System

The IP55 single phase pump control box features comprehensive safety mechanisms with adjustable response times:

Protection Trip Delay

Fault Name

Trip Response Times

Parameter Setting Range

Inverse-time over current protection

<1 second (User adjustable)

Refer to the inverse-time overcurrent curve.

When motor current continuously exceeds the rated value, the 3S intelligent pump controller trips based on the relationship between current magnitude and duration. The higher the overload current, the faster the trip; near the rated value, short-time overload is tolerated. This prevents motor overheating and burnout while allowing normal operation under brief overload conditions.

Under Current Protection

5 second (User adjustable)

1~120S

When the pump experiences low load due to water shortage, pipeline blockage, or mechanical faults, the motor current falls below the normal range. Underload protection detects this abnormal condition in time, preventing dry running or idle operation and protecting the equipment.

Locked Rotor Protection

3 second (User adjustable)

1~120S

When the pump impeller is jammed by foreign objects or the shaft cannot rotate, the motor may lock, causing a rapid current surge. Locked-rotor protection detects this condition immediately and disconnects power, preventing motor burnout.

Blockage Protection

5 second (User adjustable)

1~120S

When the pump’s inlet or outlet pipeline is blocked by debris, sediment, or valve failure, the flow is severely restricted, causing abnormal motor operation. Blockage protection promptly detects the issue and takes action to prevent motor overload or damage.

Short Circuit

1 second

Non-adjustable

When a short circuit occurs in the motor or circuit, the protection device immediately disconnects power to prevent motor damage and fire hazards.

Overvoltage Protection

5 second (User adjustable)

1~120S

When the supply voltage rises abnormally (due to lightning, grid fluctuation, or unstable power), the motor is exposed to excessive electrical stress, which may cause insulation aging, overheating, or burnout. Overvoltage protection effectively prevents damage to the motor and controller.

Undervoltage Protection

5 second (User adjustable)

1~120S

When the supply voltage is too low, the motor torque becomes insufficient, causing difficult operation, overheating, reduced efficiency, or even winding damage. Undervoltage protection prevents the motor from operating under inadequate voltage, ensuring equipment safety.

Flexible Control & Compatibility

Multiple Control Modes: Supports manual, automatic, timer, and remote control for intelligent management

Wide Signal Support: Compatible with 10 signal types including float switches, electrode probes, pressure switches, and 4-20mA sensors

Communication Interface: RS485 module for system integration

Typical Applications

Application Type

On-site Challenges

3S intelligent pump controller Solutions

Industrial Equipment Retrofit

Frequent failures of old equipment affecting production efficiency

Supports multiple signal inputs and intelligent fault diagnosis, reducing false alarms and improving reliability and stability of the equipment.

Small Building Pump Room

Limited space, requiring stable and easy-to-maintain equipment

Compact design with flexible installation, supporting timed and remote control, and reducing maintenance workload.

Groundwater Well System

Humid and dusty conditions, high equipment protection requirements

IP55 single phase pump control box tight sealing and superior protection design, tested for 360°water resistance and dust resistance, safeguarding internal circuits from short circuits or damage, ensuring safe operation in extreme environments.

Maintenance Instructions

Regularly clean controller enclosure and sealing strips to prevent dust and water stains from accumulating.

Inspect wiring terminals and grounding connections every quarter to ensure they are secure.

Monitor the fault log and promptly eliminate potential issues.

In corrosive environments such as seaside locations, it is recommended to install a sun/rain cover to extend the device lifespan.

Frequently Asked Questions (FAQ)

Q1: How Many Electrode Probes does the IP55 single phase pump control box support?

A1:For water supply: Supports up to 5 electrode probes for high-level stop, low-level start, and dry-run protection.

For drainage: Supports up to 3 electrode probes for high-level start, low-level stop and overflow alarm.


Q2: How to Prevent Impeller Corrosion During Prolonged Pump Downtime?

A2: The 3S intelligent pump controller supports an automatic anti-rust function that periodically starts the pump for a short duration to prevent impeller seizure. Both the cycle interval and run time are adjustable.

Technical Support

We offer comprehensive technical support to ensure smooth product selection, installation, and ongoing maintenance.

What'sapp

Ada

What'sapp

May

E-mail

E-mail

Wechat

Wechat

wechat